ETA Calculation Algorithms

All ETA math lives in octoprint_temp_eta/calculator.py as stateless module-level functions. The plugin class only selects the algorithm, feeds it the per-heater history and broadcasts the result — see Data flow.

There are four estimators:

Function Direction Model Default window
calculate_linear_eta Heating Constant rate (endpoint slope) 10 s
calculate_exponential_eta Heating First-order exponential 30 s
calculate_cooldown_linear_eta Cooling Constant rate (endpoint slope) 60 s
calculate_cooldown_exponential_eta Cooling Newton's law of cooling 60 s

All functions return the estimated seconds to target, or None when no trustworthy estimate is possible. The plugin hides ETAs below one second, so "almost there" never flickers a 0:00 countdown.

Heating history samples are (timestamp, actual_temp, target_temp) tuples; cooldown history samples are (timestamp, actual_temp) tuples. Both are kept in bounded deques (see the history_size setting). Windows are anchored to the newest sample timestamp, not the wall clock, so stale histories don't silently shrink to zero usable samples.

Linear heating ETA

The default algorithm (algorithm: "linear") assumes a constant heating rate.

Theory

rate = ΔT / Δt          (°C per second)
ETA  = (T_target - T_now) / rate

How it works

calculate_linear_eta(history, target, window_seconds=10.0):

  1. Rejects non-finite targets and non-positive windows.
  2. Filters the history to finite samples within the last window_seconds (relative to the newest sample) and needs at least 2 of them.
  3. Takes the first and last sample of that window and computes the endpoint slope. It intentionally does not fit all points: printer heating is noisy at ~2 Hz sampling, and the endpoints over a short window average that noise well enough while staying O(n) with a tiny constant.
  4. Requires the heater to actually be heating (ΔT > 0, Δt > 0) and below target (target - T_now > 0); otherwise returns None.

Strengths and limits

  • Fast and robust — works well during the initial heating ramp where the rate really is nearly constant.
  • Overestimates near the target — real heaters slow down as they approach the setpoint (thermal losses grow with temperature), which the linear model can't see.

Exponential heating ETA

Selectable via algorithm: "exponential". Models the slowdown near the target as a first-order exponential approach:

T(t) = T_target - (T_target - T_0) * e^(-t/tau)

where tau is the thermal time constant.

Fit and fallbacks

calculate_exponential_eta(history, target, window_seconds=30.0):

  1. Filters the window like the linear variant and drops duplicate timestamps. Fewer than 6 usable samples → falls back to the linear estimate.
  2. Returns None when already at/above target or when the window shows no meaningful heating (rise ≤ 0.2 °C).
  3. Returns 0.0 when the remaining delta is inside the convergence band ε = 0.5 °C (an exponential never mathematically reaches its asymptote, so "arrived" means "within ε").
  4. Fits a line to ln(target - T) over time via least squares (_linear_regression). The slope b maps to the time constant tau = -1/b.
  5. Sanity-checks the fit — all of these fall back to the linear estimate:
  6. fewer than 6 log-transformed points, or a time span under 5 s
  7. slope not meaningfully negative (b >= -1e-4, i.e. not converging)
  8. implausible time constant (tau > 2000 s)
  9. any ValueError/ArithmeticError from the math
  10. Computes ETA = tau * ln((target - T_now) / ε).
  11. Spike protection: if the exponential ETA exceeds 5× the linear estimate, the linear value is returned instead. A noisy fit close to the asymptote can otherwise produce absurdly long countdowns.

Accuracy trade-offs

  • More accurate near the target, where the linear model overestimates.
  • Needs more data (≥ 6 samples spanning ≥ 5 s) and degrades to linear when it can't get a trustworthy fit — the user always gets some estimate.

Linear cooldown ETA

Used in cooldown_mode: "threshold" — countdown to a fixed per-heater temperature (e.g. "bed safe to touch at 40 °C").

calculate_cooldown_linear_eta(cooldown_history, goal_c, window_seconds=60.0) mirrors the linear heating estimator with inverted signs:

  • The endpoint slope must be meaningfully negative (< -1e-3 °C/s); a heater that only drifts is treated as "not cooling" and gets no ETA.
  • The current temperature must still be above the goal.
  • The result is capped at 24 hours.

Exponential cooldown ETA

Used in cooldown_mode: "ambient" — countdown until the heater is "near ambient". Passive cooling follows Newton's law of cooling:

T(t) = T_ambient + (T_0 - T_ambient) * e^(-t/tau)

calculate_cooldown_exponential_eta(cooldown_history, ambient_c, goal_c, window_seconds=60.0):

  1. Requires goal_c > ambient_c (the goal must be reachable by passive cooling) and at least 4 samples; fewer than 6 samples in the window → falls back to the linear cooldown estimate.
  2. Fits ln(T - T_ambient) over time, requiring at least 4 usable points, a negative slope, and a plausible time constant (0 < tau <= 20000 s).
  3. Computes ETA = tau * ln((T_now - T_ambient) / (goal - T_ambient)), capped at 24 hours.

The ambient temperature comes from the cooldown_ambient_temp setting when set; otherwise the plugin learns a baseline from the lowest temperature observed while the heater is off (see _get_cooldown_ambient_c in __init__.py).

How the plugin drives the estimators

The plugin (not the calculator) decides when an estimate is computed and shown — see Data flow for the full pipeline:

  • Heating samples are recorded only while a heater has an active target and is more than threshold_start degrees below it; holding at temperature records nothing, so the fit window always reflects an actual ramp.
  • Cooldown samples are kept in a separate history that is cleared on the heating → off transition, so old pre-heat data never pollutes the cooling fit.
  • ETAs under 1 second are suppressed, and heaters not present in the active printer profile are skipped entirely.

Edge cases

  • Target changes mid-heat: history is not cleared; the window (10/30 s) ages the old ramp out quickly, and the persistence backoff schedule is reset (target_change) so fresh data is persisted soon.
  • Stalled heating: no temperature rise in the window → None → the UI shows the idle state instead of a frozen countdown.
  • Overshoot / already there: remaining <= 0None (heating) or T_now <= goalNone (cooling).
  • Bad samples: non-finite timestamps/temperatures are filtered out before fitting; math errors inside a fit degrade to the simpler estimator instead of raising into OctoPrint's callback thread.

Configuration

Real settings that influence the algorithms (see Configuration for the full list):

plugins:
  temp_eta:
    algorithm: "linear" # or "exponential" (heating only)
    threshold_start: 5.0 # start showing ETA within this delta (°C)
    update_interval: 1.0 # seconds between frontend updates
    history_size: 60 # samples kept per heater
    enable_cooldown_eta: true
    cooldown_mode: "threshold" # or "ambient"
    cooldown_fit_window_seconds: 120 # cooldown fit window
    cooldown_ambient_temp: null # fixed ambient (ambient mode), else learned

Performance

Both heating estimators run inside OctoPrint's temperature callback (~2 Hz), so they are deliberately allocation-light and pure Python — no numpy/scipy dependency:

  • Linear: one filtered pass over ≤ history_size samples, then O(1) endpoint math.
  • Exponential: one filtered pass plus a least-squares fit over the ≤ 60 windowed samples; well under a millisecond on a Raspberry Pi class device.

Testing

The estimators are pure functions, which keeps their tests trivial to write — see tests/test_calculator.py:

def test_heating_linear(self):
    """Constant 2 °C/s ramp, 30 °C remaining -> 15 s."""
    history = deque([(0.0, 20.0, 60.0), (5.0, 30.0, 60.0)])
    result = calculator.calculate_linear_eta(history, 60.0, window_seconds=10.0)
    self.assertAlmostEqual(result, 15.0, places=3)

See Testing for the full suite.